Model 675 User Instructions 5
1.4 Electrical Installation
1.4.1 Pluggable Equipment
Pluggable equipment must be installed near an easily accessible socket outlet.
1.4.2 Permanently Wired Equipment - Isolator Requirements
Permanently connected equipment must have a readily accessible disconnect device
incorporated in the fixed wiring such as an isolator or circuit breaker with at least 3mm
contact separation.
The isolator MUST NOT be installed into the flexible power cable supplied with the unit.
1.4.3 Safe Handling of Equipment with Batteries
1.4.4 Wet Conditions
The Model 675 is not a washdown unit. Do not install near water.
CAUTION: The power cable must be connected to an earth-grounded electrical
outlet. The electrical supply must have a circuit breaker with an appropriate
rating to protect from over-current conditions.
Do not install the Model 675 in wet or damp conditions!
IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN.
Danger of explosion if battery is incorrectly replaced. Replace only with the
same or equivalent type recommended by the manufacturer. Dispose of used
batteries according to the manufacturer’s instructions.
ATTENTION: Il y a danger d'explosion s'il y a remplacement incorrect de la
batterie, remplacer uniquement avec une batterie du même type ou d'un type
équivalent recommandé par le constructeur. Mettre au rebut les batteries
usagées conformément aux instructions du fabricant.