GSE 675 - Set Modes for Operation

GSE 675
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22 Model 675 User Instructions
2.2.7 Set Modes
After choosing a display style there are several modes of operation (such as Gross and
Quantity) to choose from. These modes are accessible by using the [SELECT] key
while viewing the Application Menu mode. The ability exists to enable or disable each
choice.
1. Press [F4] to access the Set Modes menu.
2. Use the [F1] Next Mode key to toggle through the available modes.
3. Use the [F2] Enable Mode key to enable the mode.
4. Use the [F3] Disable Mode key to disable the mode.
5. Press [F5] to exit back into the APW Lookup screen.
Print Menu
Preset Print Formats
The preset print formats are viewable on the LCD display. Use the [F3] left arrow and
[F4] right arrow keys to view all transmit styles. Chose the desired format by viewing it
on the screen. Press the [F5] (EXIT) key to save the format and return to the main
menu.
Parameter Description Default Setting Keypresses
PRINT PART#S Print stored part numbers to printer or computer Not applicable Print data to comm. 1, 2 or display.
Use [F1] or [F2]
D-LOAD PART#S Download part number, description, average piece
weight and tare weight in comma delimited format
Not applicable Print data to comm. 1or 2. Use
[F1] or [F2]
PRINT
FORMATS
Choose what information to print out Print Style 1 Use [F3] and [F4] to view print
format choices. Press [F5] to save
the format
QTY: 964
APW:
Tare
Print #1
6/30/10
Part# 123456
Description Drywall Screws
Net
Gross8.363 lb
1.133 lb
7.230 lb 0.0075 lb
Print #2
Part# 123456789
APW 0.017823
Tare 2.5143

Other manuals for GSE 675