The header contains more that twelve
characters (see IEEE 488.2, 7.6.1.4.1).
The header is syntactically correct, but it is
undefined for this specific device; for example,
*XYZ is not defined for any device.
The value of a numeric suffix attached to a
program mnemonic, see Syntax and Style
section 6.2.5.2, makes the header invalid.
The number of parameters received does not
correspond to the number of parameters
expected. This is typically due an inconsistency
with the number of instruments in the selected
group.
This error, as well as errors -121 through -129,
are generated when parsing a data element
which apprears to be numeric, including the
nondecimal numeric types. This particular error
message should be used if the device cannot
detect a more specific error.
An invalid character for the data type being
parsed was encountered; for example, an alpha
in a decimal numeric or a “9" in octal data.
A legal numeric data element was received, but
the device does not accept one in this position
for the header.
The suffix does not follow the syntax described
in IEEE 488.2, 7.7.3.2, or the suffix is
inappropriate for this device.

Table of Contents

Other manuals for GW Instek ASR-2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek ASR-2000 Series and is the answer not in the manual?

GW Instek ASR-2000 Series Specifications

General IconGeneral
BrandGW Instek
ModelASR-2000 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals