REMOTE CONTROL
79
<NR2>
Returns the Irms.
:CURR:LIM:RMS?
5.25
Returns the Irms setting.
[:SOURce]:CURRent:LIMit:PEAK:MODE
Set
Query
Sets or queries Ipk limit enabled or disabled.
[:SOURce]:CURRent:LIMit:PEAK:MODE
{<bool>|OFF|ON}
[:SOURce]:CURRent:LIMit:PEAK:MODE?
<bool>
|OFF (0)|ON (1)
OFF
Ipk limit off
ON
Ipk limit on
:CURR:LIM:PEAK:MODE ON
Sets Ipk limit enabled.
[:SOURce]:CURRent:LIMit:RMS:MODE
Set
Query
Sets or queries IRMS OC-Fold enable.
[:SOURce]:CURRent:LIMit:RMS:MODE
{<bool>|OFF|ON}
[:SOURce]:CURRent:LIMit:RMS:MODE?
<bool>
|OFF (0)|ON (1)
OFF
IRMS limit off
ON
IRMS limit on
:CURR:LIM:RMS:MODE ON
Sets IRMS limit enabled.
[:SOURce]:FREQuency:LIMit:HIGH
Set
Query
Sets or queries the frequency upper limit range.
(Only AC+DC-INT or AC-INT or AC+DC-ADD or
AC-ADD Active)