REMOTE CONTROL
71
:SYSTem:COMMunicate:SERial[:RECeive]:TRANsmit
:BITS <NR1>
:SYSTem:COMMunicate:SERial[:RECeive]:TRANsmit
:BITS?
0
7 bits
1
8 bits
+0
7 bits
+1
8 bits
SYST:COMM:SER:TRAN:BITS?
>+1
Indicates that 8 data bits are used for the UART
connection.
:SYSTem:COMMunicate:SERial[:RECeive]
:TRANsmit:PARity
Set
Query
Sets or queries the parity of the UART connection.
The setting will only be valid after the power has
been cycled.
:SYSTem:COMMunicate:SERial[:RECeive]:TRANsmit
:PARity {NONE|ODD|EVEN}
:SYSTem:COMMunicate:SERial[:RECeive]:TRANsmit
:PARity?
NONE
No parity
ODD
Odd parity
EVEN
Even parity
+0
No parity
+1
Odd parity
+2
Even parity
SYST:COMM:SER:TRAN:PARity?
>+0
Indicates that no parity is used for the UART connection.