REMOTE CONTROL
95
:SIM:ABN:FREQ 55
Sets the frequency to 55Hz.
[:SOURce]:SIMulation:ABNormal:PHASe
:STARt:ENABle
Set
Query
Enables/Disables (Fixed/Free) the ON Phs parameter
of the abnormal step for the Simulation mode.
[:SOURce]:SIMulation:ABNormal:PHASe:STARt
:ENABle {<bool>|OFF|ON|FREE|FIXED}
[:SOURce]:SIMulation:ABNormal:PHASe:STARt
:ENABle?
OFF | 0 |
FREE
Disabled
ON | 1 |
FIXED
Enabled
:SIM:ABN:PHAS:STAR:ENAB 1
Enable the ON Phs.
[:SOURce]:SIMulation:ABNormal:PHASe
:STARt[:IMMediate]
Set
Query
Sets or queries the ON Phs parameter of the
abnormal step for the Simulation mode.
[:SOURce]:SIMulation:ABNormal:PHASe:STARt
[:IMMediate] {<NR2>|MINimum|MAXimum}
[:SOURce]:SIMulation:ABNormal:PHASe:STARt
[:IMMediate]? [MINimum|MAXimum]
<NR2>
ON Phs (start phase)
MINimum
0
MAXimum
359
:SIM:ABN:PHAS:STAR 0
Sets ON Phs to 0.