TEST MODE FUNCTION 
163 
Manage Sequence Settings 
Sequence settings can be easily saved to or from a USB flash drive 
using the Save/Recall Files utility in the Menu system. Files can 
also be deleted from local memory using the utility. 
 
When files are saved to USB they are saved in 
the following format: 
SEQX.SEQ, where X is the memory number  
0 ~ 9 (SEQ0 ~ SEQ9). The files are saved to 
USB:/gw. 
When files are recalled from USB, files must be 
recalled from the same memory number. For 
example, the file SEQ0. SEQ can only be recalled 
to memory number SEQ0. The files can only be 
recalled from the USB:/gw directory.  
1.  Press the Menu key. The Menu 
settings will appear on the display. 
2.  Use the scroll wheel to go to item 10, Save/Recall 
Files and press Enter. 
3.  Go to the Type setting using the scroll wheel 
and press Enter. Select SEQUENCE and press 
Enter to confirm.  
4.  Go to the Action setting and choose the file 
operation and then press Enter.  
Saves the selected sequence 
memory from the local memory 
to a USB flash drive. 
Loads the sequence memory 
from a USB flash drive to the 
selected local memory.