To minimize noise pickup or radiation, the load
wires and remote sense wires should be twisted-
pairs of the shortest possible length. Shielding of
the sense leads may be necessary in high noise
environments. Where shielding is used, connect
the shield to the chassis via the rear panel
ground screw. Even if noise is not a concern, the
load and remote sense wires should be twisted-
pairs to reduce coupling, which might impact
the stability of the power supply. The sense
leads should be separated from the power leads.