51
Usage guidelines
For controllers to manage a site-facing interface, you must specify the interface as a VTEP access
port.
Examples
# Specify GigabitEthernet 1/0/1 as a VTEP access port.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] vtep access port
vtep acl disable
Use vtep acl disable to disable the ACLs issued by the OVSDB controller.
Use
undo vtep acl disable to enable the ACLs issued by the OVSDB controller.
Syntax
vtep acl disable
undo vtep acl disable
Default
The ACLs issued by the OVSDB controller are enabled on the device.
Views
System view
Predefined user roles
network-admin
Usage guidelines
Before you use this command, you must use the vtep enable command to enable the OVSDB
VTEP service.
Use the
vtep acl disable command on a VTEP to disable all the ACLs issued by the OVSDB
controller in order to save ACL resources on the VTEP.
Examples
# Disable the ACLs issued by the OVSDB controller.
<Sysname> system-view
[Sysname] vtep enable
[sysname] vtep acl disable
Related commands
vtep enable
vtep enable
Use vtep enable to enable the OVSDB VTEP service.
Use
undo vtep enable to disable the OVSDB VTEP service.
Syntax
vtep enable
undo vtep enable