EasyManua.ls Logo

Haldex EB+ Soft Docking - Vertical Mounted Sensor; Sensor Beam Detection Zone

Haldex EB+ Soft Docking
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EB+ Soft DockingInstallation guide
21
2020 Innovative Vehicle Solutions
Vertical mounted sensor
min 35 cm
min 35 cm
min
65 cm
Vertical mounted sensor
The sensor shall be mounted at minimum 35cm from
the lateral edge of the trailer, and 65cm from the
ground. This is to avoid detection of other vehicles /
obstacles on the side of the trailer.
If 35 cm is not possible, angular adjustment maybe
required by using the sensor notches, 3 x 6° notches
for each side.
Drill a 25 mm diameter hole, pass the sensor lead
through with connector from the sensor. Fix the sensor
with two fixing screws onto the trailer. Plug the cable
into the connector from the EB+ Soft Docking cable
loom.
See below, the yellow shaded zone shall be free of any
object when installing the sensor. Refer to drawing
3646140002 for further information.
Sensor beam detection zone
20 cm
60 cm
Sensor beam profile
84 cm 107 cm