Manual
NP100
Programmable Controller
Question and Answer IconNeed help?

Do you have a question about the HANYOUNG NUX NP100 and is the answer not in the manual?

HANYOUNG NUX NP100 Specifications

General IconGeneral
ModelNP100
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 70°C
TypePLC Controller
CommunicationRS-485
Programming LanguageLadder Logic
Input TypeDigital Input (DI)

Summary

1. SAFETY INFORMATION

5. INPUT & OUTPUT

Input type and Measurement range

Details the available input types and their corresponding measurement ranges.

6. NAME & FUNCTION

6-2. Function of control key

Explains the operation and functions of the various keys on the controller's front panel.

7. LIST OF SETUP ITEMS

8. SETUP METHOD

8-1. Engineering Group Setup

Steps to configure the controller's basic functions via the engineering mode.

8-1-1. Input Setup group

Configures the input signal type, measurement range, and decimal point settings.

8-2. Program Group Setup

Guides on setting up program repeat frequency and sequence parameters.

8-2-1. Setup Group for Program Repeat Frequency

Sets the number of times a program pattern will repeat, including limitless options.

8-2-2. Program Setup Mode

Configures pattern number, start set value, start type, time signals, and completion modes.

Program mode overview

Illustrates the flow for setting up and running control programs.

8-1-2. Output Setup Group

Sets up output types, heating/cooling control, cycle time, and hysteresis.

8-1-3. Communication Setup Group

Configures communication protocol, speed, parity, stop bits, data length, address, and response time.

8-1-4. Retransmission Setup Group

Sets retransmission output type, maximum, and minimum output values.

8-1-5. Alarm Setup Group

Configures alarm types, dead bands, set values, and pattern ending signals.

8-1-6. Control Setup Group

Sets fuzzy function, time unit, wait zones, wait time, and power recovery modes.

8-1-7. PID Setup Group

Configures PID parameters including Anti Reset Wind Up, Proportion, Integral, and Differential.

8-1-8. Auto Tuning Setup Group

Sets up auto tuning type, operation, and stop conditions for PID optimization.

9. SPECIFICATION

9-1. Input

Details input types, ranges, resolution, resistance, and allowable signal source.

10. ALARM TYPE AND CODE

12. PROGRAM SETUP CHART