Control Panels for X75 Systems Installation and Operation Manual 47
Chapter 2: Operation via Front Panel Controls
Priority
Alarm Mute
Acknowledged
Alarms Log: The last 20 alarms (minor and major) are listed in the
Alarms Log. This is a read-only list; it can only be cleared by
disconnecting power to the control panel.
Configure Alarms: Use this parameter to set the parameters for
alarms on your network of X75-RC-enabled devices. For each
alarm, you can access the following options:
•Trigger Time
•Clear Time
Priority
Alarm Mute
Acknowledged
Favorite 1 and Favorite 2: Use these two lists to retain the ten
most-needed parameters. With each parameter listing that you wish
to save, press Favorite 1 or Favorite 2 from the Options List, and
then select Add. The message “Item added” appears. See “FAV1
and FAV2 (Favorites1 and Favorites2)” on page 36 for more
information.
Preset: This shortcut leads you directly to the Memory menu (see
“Memory” on page 41).
MuteKeepAlive: The X75HD/X75SD unit sends out a “keepalive”
message every 15 seconds (approximately). The keepalive checks
to determine if the device is still active and resides on the control
network. The following options are available:
No: The keepalive message is broadcast every 15 seconds by
the X75 unit to be discovered by the client control systems.
Yes: Suppresses the keepalive message unless it is requested by
any client control system.
If the X75 is re-powered with the Mute KeepAlive option set to
Yes, a client device such as a remote control panel will not be able
to discover the unit until the control panel is re-powered.
Home: This option returns you to the Main menu.