DA-6804+D Series
Installation and Operation Manual
35
Copyright © 2010, Harris Corporation
Table 3-4 DA-DHR6804+D/DA-DH6804+D/DA-DSR6804+D/DA-DS6804+D
Remotely Controlled Parameters
Bold text = Default setting [RO] = Read only/feedback
Path Parameter Range Description
Processing Serial Number [RO] String Serial number for the module
License Key String License key number for the module
Other Output Config.
Ch.1 1×8 with ACO
Ch.1 1×8
Ch.2 1×8
2×4
Selects module output configuration
as dual 1×4 or 1×8, 1 input routed to
all outputs; or 1×8 with input 2 routed
to all outputs
Ch.1 Signal Present [RO]
No
Yes
Indicates if the input signal for
channel 1 is present or not
Ch.2 Signal Present [RO]
No
Yes
Indicates if the input signal for
channel 2 is present or not
Ch.1 Loss of Input Alarm
Disabled
Enabled
Enables or disables the Loss of Input
alarm for channel 1
Ch.2 Loss of Input Alarm
Disabled
Enabled
Enables or disables the Loss of Input
alarm for channel 2
Current Input [RO]
NOTE: Only valid in 1×8
with ACO mode output
configuration
N/A
Ch. 1
Ch. 2
Indicates if the input signal is channel
1 or channel 2
Ch. 1 Slew Rate
SD
HD
Auto
Controls output/rise fall time for
channel 1
SD – Output Rise Fall time complies
with SMPTE 259M
HD – Output Rise Fall time complies
with SMPTE 424M /292M
Auto – Automatically selects proper
rise fall time based on incoming
signal
Ch. 2 Slew Rate
SD
HD
Auto
Controls output/rise fall time for
channel 2
SD – Output Rise Fall time complies
with SMPTE 259M
HD – Output Rise Fall time complies
with SMPTE 424M /292M
Auto – Automatically selects proper
rise fall time based on incoming
signal
Parameter Hysteresis 0.1 to 0.5 seconds Value used to determine how long a
condition (that is, signal presence)
must be asserted before it is reported
to the control system