EasyManua.ls Logo

HBM MP55 - Page 63

HBM MP55
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62
PME-MP55
HBM A0563-5.6 en
Control outputs
Number
Rated voltage, external power supply
Permitted supply voltage range
Output current, max.
Short-circuit current, typically
Short-circuit period
Test voltage, typical
V
V
A
A
V
DC
4
24
18...30
0.5
0.8
unlimited
500
Control inputs
Input voltage range, LOW
Input voltage range, HIGH
Input current, typically, HIGH value =
24 V
Test voltage typical
V
V
mA
V
DC
4
0...5
10...30
12
500
Interface
Sampling rate, approx.
Protocol
Hardware bus link
baud rate
Maximum length of cable
kBit/s
m
Maximum 1000 samples/sec.
CAN 2.0B, CAL/CANopen compatible
in accordance with ISO11898
1000 800 500 250 125 50 20 10
25 50 100 250 500 1000 1000 1000
Parameter memory (EEPROM) 4 (plus factory setting)
Display
Type
Keyboard
2-line, 8-digit alphanumeric, LCD
Touch-sensitive keyboard with 3 control
buttons
Rated temperature range
Service temperature range
Storage temperature range
°C [°F]
°C [°F]
°C [°F]
0...50 (32...122)
-20...+50 (-4...122)
-20...+70 (-4...158)
Protection class IP20
Dimensions, overall (W x H x D) mm 55 x 146 x 162
Weight, approx. g 470
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com