5 Inputs
64 A04089_07_E00_02 HBM: public MX Modules
5 Inputs
5.1 Strain gage transducers
Transducer MX840B-R MX1615B-R MX411B-R
Strain gage, full bridge
six-wire configuration
Strain gage, half bridge
five-wire configuration
Strain gage, quarter bridge
three- or four-wire configuration
*
3-wire only
*
3-wire only
*
Use quarter bridge adapter 1-SCM-R-SG1000-2, 1-SCM-R-SG120-2 or 1-SCM-R-SG350-2.