EasyManua.ls Logo

HCS DAC-42A - Example, Write Set Value

HCS DAC-42A
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DAC-42(A)-x-PN
Page 46
DAC-42(A)-x-PN
Manual
Revision: 1.0
22.01.2024
8.4.2 Example, write set value
Examples for set value via Profinet (ID = 0x0027):
1.) Command signal 0.000 V = 0x0000:
Byte
Data
Abbreviation
0
0x12
TADR
1
0x01
SADR
2
0x06
CMD
3
0x00
IDH
4
0x27
IDL
5
0x00
DATL
6
0x00
DATH
2.) Set value 5.000 V = 0x1388:
Byte
Data
Abbreviation
0
0x12
TADR
1
0x01
SADR
2
0x06
CMD
3
0x00
IDH
4
0x27
IDL
5
0x13
DATL
6
0x88
DATH
3.) Set value 9.999 V = 0x270F:
Byte
Data
Abbreviation
0
0x12
TADR
1
0x01
SADR
2
0x06
CMD
3
0x00
IDH
4
0x27
IDL
5
0x27
DATL
6
0x0F
DATH
4.) Set value –9.999 V = 0xD8F1
Byte
Data
Abbreviation
0
0x12
TADR
1
0x01
SADR
2
0x06
CMD
3
0x00
IDH
4
0x27
IDL
5
0xD8
DATL
6
0xF1
DATH