02/11/98
19
1) Hold down the SET button until the numeric display says SEL.
2) Now press the SEL button 11 times until
F0i appears in the display. You are
now at F01 in the FUNCtion mode.
3) Press SEL again until the function you wish to set up appears.
4) Press the SET button to show the current value of the function you have selected.
5) To change the function value, press SET. The display will scroll through the range of
available values. Stop scrolling when the value you wish appears in the display.
6) If you are only changing one function, simply leave the unit alone and in 3 seconds, the
display will return to normal and the choice you have made for the function selected will
be stored in memory.
7) If you wish to set up other functions, press the SEL button right away after making
your selection in Step 5. You'll now scroll on to the next function, which can be changed
the same way. When you have made all the changes desired, simply leave the unit alone
for 3 seconds and the values will be memorized and the display returned to normal opera-
tion.
FUNCTIONS TABLE
The above section gave you the general approach to changing an Advanced Function
setting. Now, we'll go through each of the Advanced Functions and explain what each
does and how you may wish to use it. If you ever get "lost" and want to restore all factory
default settings, simply follow the RESET procedure on Page 25!
F01 - AUTO DISPLAY SCANNING
DEFAULT = OFF RANGE: OFF, ON
Automatically scans through the major displays: Volts, Amps, Amp-hours, and Time
of Operation remaining. Each value is displayed for 4 seconds.
If second battery voltage sensing (F11) is ON, 2 voltages are shown: The flashing
Volts status light indicates the voltage displayed is that of the second battery bank.
HOW TO SET UP FUNCTIONS
When the FUNC light is on,
you can access Advanced
Functions of the
Link 1000
.
The values for each function
are changed using the SET
and SEL keys.