366 10 Programming: Q Parameters
10.7 Checking and changing Q parameters
10.7 Checking and changing Q
parameters
Procedure
During a program run or test run, you can check or change Q
parameters if necessary.
U If you are in a program run, interrupt it (for example by pressing the
machine STOP button and the INTERNAL STOP soft key). If you are
doing a test run, interrupt it.
U To call the Q parameter functions, press the Q key.
U Enter the Q parameter number and press the ENT key.
The TNC displays the current value of the Q
parameter in the dialog line.
U If you wish to change the value, enter a new value,
confirm it with the ENT key and conclude your entry
with the END key.
U To leave the value unchanged, terminate the dialog
with the END key.