EasyManua.ls Logo

Henry Schein Urispec Plus User Manual

Henry Schein Urispec Plus
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Henry Schein Urispec Plus and is the answer not in the manual?

Henry Schein Urispec Plus Specifications

General IconGeneral
BrandHenry Schein
ModelUrispec Plus
CategoryMedical Equipment
LanguageEnglish

Summary

Quickstart Guide

Introduction and Intended Use

Intended Use and Indications

Details the intended applications and indications for the Urispec® Plus urine analyzer.

Measuring Principle Explained

Explains the reflectometric analysis principle used by the Urispec® Plus.

Functional Principle of Urispec® Plus

Describes how the Urispec® Plus operates, including measurement initiation.

Safety Warnings and Symbols

Defines DANGER, ATTENTION, and NOTE symbols used throughout the manual for safety.

Device Labels and Symbols

Details product labels for the Urispec® Plus and its test strips.

Explanation of Symbols

Provides meanings for various symbols used in the Urispec® Plus user manual.

Unpacking and Setup

List of Delivered Parts

Lists all components included in the Urispec® Plus package.

Instrument Parts Description

Setting Up the Instrument

Provides guidelines for properly placing and acclimating the instrument.

Connecting the Power Supply

Loading the Printer Paper

Instructions for opening the printer flap and loading paper.

Installing Batteries (Optional)

Instrument Self-Test Procedure

Describes the automatic self-test performed when the instrument is turned on.

Automatic Calibration

Explains that the instrument performs automatic calibration for each test run.

Using the Instrument

Instrument Buttons Explained

Details how framed areas and buttons on the touch-screen function.

Using Scroll Arrows

Instructions on using scroll arrows to navigate lists and confirm selections.

Understanding Round Buttons

User Menu Navigation

Menu Structure Flowchart

Visual representation of the instrument's menu hierarchy and options.

Description of Menu Items

Analysis of Test Strips

Selecting the Test Strip

Instructions on how to select the correct test strip type for analysis.

Performing a Measurement

Step-by-step guide on how to perform a urine sample measurement.

Display of Results

Troubleshooting Measurement Errors

Guidance on how to handle and resolve measurement errors.

Entering Patient Identification

Procedure for entering patient identification before starting analysis.

Entering Patient Identification Methods

Changing Sequence Number (SN)

Transferring Data to PC

Information on how to transfer measurement results to a computer.

Accessing the Main Menu

Recalling Measurement Results

Scrolling Through Memory

Instructions for navigating through stored measurement results in memory.

Finding Specific Results (Filtering)

Selecting the Date for Filtering

Guide on selecting a specific date to filter measurement results.

Selecting Search Criteria

Displaying Search Results

How to view measurement results that match the selected filter criteria.

Deleting Results from Memory

Expected Waiver Performance

Quality Control Testing

Running a Quality Control Test

Procedure for performing quality control tests using negative and positive samples.

Reviewing Old QC Measurements

Equipment Settings

Modifying Strip Settings

Instructions for changing units and parameter order for test strips.

Protecting Settings with a PIN

Procedure for setting up PIN protection for instrument settings.

Printer On/Off Control

Acoustic Signal Settings

How to enable or disable acoustic signals for user inputs and positive results.

Autostart Function Control

Instructions for deactivating or activating the automatic test strip detection.

Battery Mode Energy Saving Options

Settings to conserve battery life, like turning off backlight and printer.

Changing the Language

Setting Time and Date

Procedure for setting the instrument's internal time and date.

Activating Data Transfer

How to enable or disable data transfer via the instrument's interfaces.

Customizing Printout Header Text

Printing Equipment Settings

Instructions on how to print current equipment settings for documentation.

Cleaning and Maintenance

Cleaning the Instrument Housing

Guidelines for wiping the instrument housing with mild cleaning agents.

Cleaning the Strip Holder

Procedure for cleaning the strip holder, including removal and reattachment.

Table of Results

Service Menu Access

Resetting the System (Load Default)

How to reset the instrument to its original delivery status and clear memory.

Updating the Instrument Firmware

Instructions for uploading and installing new firmware for the instrument.

Interface Description

Serial Interface Details

Information on the RS232 serial interface, protocol, and connection plug.

USB 1.1 Interface

Details on the USB Type B interface and how the instrument is identified.

Data Transmission Protocol

Describes how data is released via interfaces and its format.

Barcode Scanner and PC-Keyboard Connection

Information on connecting a USB Type A device like a keyboard or scanner.

Ethernet Interface Status

States that the RJ45 Ethernet jack is not supported.

Error Messages and Fault Clearance

Technical Information

Technical Data Specifications

Details electric supply, dimensions, weight, memory, temperature, and humidity.

Security Standards Compliance

Information on compliance with various EU directives and ROHS standards.

Service and Support

Version History of Manuals

Lists the different versions and release dates of the Urispec® Plus user manuals.

Additional Security Standards Information

Related product manuals