EasyManua.ls Logo

HERMOS LFM 4x - Page 109

Default Icon
125 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Customer manual
LFM 4x Reader
RFID
WE GENERATE SOLUTIONS
LFM 4x Reader Rev1.3
back to the table of contents
103
www.hermos.com
23
0x17
Triggered read frequency
For a read / write error, the triggered reading frequen-
cy sets the time between two read / write attempts for a
transponder;
Read frequency in case of a triggered read (no
polling)
02 … 10 (1/10s)
Default: 5 (0,5s)
Realisation: a separate parameter for each port *)
24
0x18
r/w max repeat
Maximum number of read and write retries
0 … 255
Default: 5
Realisation: a separate parameter for each port *)
25
0x19
Transponder Type
The parameter defines the validity of the read data of
the transponder.
0 … read / write type TIRIS
Each transponder page consists of 8 data bytes and 2
bytes CRC checksum. The validity of the data bytes is
verified by a checksum
1 … A transponder page is interpreted as 10 data
bytes without checksum.
Default: 0
26
0x1A
Sensor Activity
The sensor activity of each head is represented by a
bit. For each sensor exactly one bit is provided.
0 … Sensor not activated
1 … Sensor activated
Standard: 0x0F
27
0x1B
Watchport for individual
Presence Sensor
Enables a message to the host if a sensor has been
used or if the occupancy has been removed.
A sensor is required on use this feature.
0 message no action
1 message Sensor assignment has been
removed
2 message Sensor assignment has been detected
3 …message occupancy detected and removed.
Default: 3
Realisation: a separate parameter for each port *)
29
0x1D
Transponder load duration
(read mode)
Charging time of a transponder during the reading
process.
The default setting should not be changed.
Default: 50 … (50ms)
Realisation: a separate parameter for each port *)
30
0x1E
r/w synchronize
Activates / deactivates the synchronization of the
reader.
When synchronization is enabled, the reader detects
interference or other active readers and synchronizes
the read cycle .
0 … synchronization deactivated
1 … synchronization activated
Default: 1 … activated

Table of Contents