The parameter controls the allowed triggers of an
automatic adjustment of the antenna .
0 … autom. Customization is not activated 1 ... autom.
Adaptation via DIP4
2 ... autom. Adaptation by external command 3 ...
autom. Adaptation via DIP4 or
external command
Default: 3
Type of sensor signal to start an automatic read. One bit
is provided for each sensor (Bit0 Sensor 1, ..., Bit3
Sensor 4) with the following meaning
0 … read when sensor is covered
1 … read when sensor is uncovered
Value range Parameter: 0x00 bis 0x0F
Default: 0 (reading starts on all sensors when
sensor is covered)
Bit 0: After a hardware reset, the reader will auto-read if
the presence sensor is covered.
0 ... execute read operation after reset, when sensor is
covered
1 ... Do not execute a read after reset, when the
sensor is covered (standard)
Bit 1: Trigger sensor-triggered automatic read opera-
tion
0 ... reading after detected sensor
trigger
1 ... No automatic reading with detected sensor
Bit 2: 0: non volatile memory is used for saving the
reader ID at reset process
Bit 2: 1: non volatile memory ist not used
Bit 3: without function
Bit 4: set external head LED1 at sensor triggered
read
Bit 5: page transfer when reading the first page of a
multipage transponder
0 ... without page transfer 1 ... with page transfer
Bit 6: external head LED1 will be influenced at ASC-
W1 mode
Bit 7: external head LED2 will be influenced at ASC-
W1 mode
Default: 0x01 … (0000 0001)