Hardwarerevision String
(read only)
The read-only parameter provides the complete
identifier for the hardware version.
DIP switch status (read
only)
The parameter is used to query the position of all DIP
switches.
Bit0: DIP 4 (0=off, 1=on) Bit1: DIP 3 (0=off, 1=on) Bit2:
DIP 2 (0=off, 1=on) Bit3: DIP 1 (0=off, 1=on)
The result is independent of parameter 36 (0x24).
Saved fatal errors or
events
(read only)
The read-only parameter retrieves all errors and events
stored in a ring memory. Since only about 25 characters
are read out of the memory per call, it may need to be
retrieved several times until it is completely emptied.
Fatal errors and the creation of default paramters will be
saved.
Antenna tuning of the
antenna 1
By automatically adjusting the antenna, the influence of
ambient conditions can be minimized
00 ... 15 value of antenna adjustment
Antenna tuning of the
antenna 2
Antenna tuning of the
antenna 3
Antenna tuning of the
antenna 4
Antenna tuning of the
addressed antenna
By automatically adjusting the antenna, the influence of
ambient conditions can be minimized
00 ... 15 value of antenna adjustment
Default: 08
Realisation: a separate parameter for each port *)