Via this parameter default parameters of the reader can
be established. Factor setting parameters remain
unaffected!
0... reset all parameters
1... reset all parameters except network settings
The query of the parameter returns the fine version of
the software version.
This parameter provides information about the currently
set protocol. Automatic protocol selection distinguishes
between "ASCII" and "ASCII"
1 "SECS" protocol. Setting the parameter causes the
reader to be restarted if the protocol is changed.…
SECS/HSMS
2 … ASCII
Default: 1
This parameter can be used to allow a detected
protocol change. This will then set the new default
protocol and restart the device. If the protocol change
is suppressed, no automatic change takes place.
0 … protocol change not allowed
1 ... protocol change allowed
Default: 1
Special customer parameter settings that differ from the
basic settings.
Several parameter values are set by a customer code.
The following parameters are defined:
0 … device version according to SEMI E99-0303
Par. 37 = 2
Par. 42 = 0
Par. 43 = 16
Par. 44 = 1
Par. 45 = 0
3 … device version before SEMI E99-0303
Par. 37 = 1
Par. 42 = 0
Par. 43 = 8
Par. 44 = 0
Par. 45 = 0
4 … device version without MID
Par. 37 = 0
Par. 42 = 0
Par. 43 = 0
Par. 44 = 1
Par. 45 = 0
Default: 0