Parameter Options Description
Interstitial Points
Filtering
OFF (default)
ON
To reduce the interstitial points.
Definition of interstitial points:
When a beam partially hits a front target's edge and further hits a rear target, the
return signal can result in a false point located between both targets.
Retro Multi-Reflection
Filtering
OFF (default)
ON
To reduce the false positives at twice the distance of a retroflector.
Reflectivity Mapping Linear Mapping (default)
Nonlinear Mapping
Linear
The Reflectivity field in Point Cloud Data Packets linearly
represents target reflectivity (0 to 255%).
Nonlinear Increases the contrast in low-reflectivity areas (see Appendix D
Nonlinear reflectivity mapping).
Standby Mode In Operation (default)
Standby
In Standby mode, the motor stops running and lasers stop firing.