CHAPTER 3
The Menu System
40 Studio Command Series User Manual
Resetting Fixture Hours (F/RS)
Use this menu to reset the recorded number of hours the fixture has been on.
To reset the fixture hours to zero:
1. Press and hold <Menu> until AddR appears on the LED display.
2. Scroll to the INFO menu. Press <Enter> to select.
3. Scroll to the F/RS option.
4. Press <Enter> to store the selection. The LED will display 0000 when the fixture
hours are reset.
Note: This option has a five-second delay to avoid inadvertent changes. To
reset the fixture hours, you must press and hold the <Enter> button
for at least five seconds.
Viewing the Current Fixture Hours (F/HR)
To view the number of hours the fixture has been on since this option was reset:
1. Press and hold <Menu> until AddR appears on the LED display.
2. Scroll to the INFO menu. Press <Enter> to select.
3. Scroll to the F/HR option.
4. Press <Enter>. The LED will display the number of hours the fixture has been on.
Resetting Lamp Hours (L/RS) (Studio Command 1200/700 models only)
This option (functional for Studio Command 1200/700 fixtures only) resets the hours the
current lamp has been operating to zero. You should reset the lamp hours each time you replace
the lamp (see Replacing the Lamp on page 58).
To reset the current lamp hours to zero:
1. Press and hold <Menu> until AddR appears on the LED display.
2. Scroll to the INFO menu. Press <Enter> to select.
3. Scroll to the L/RS option.
4. Press <Enter>. The LED will display 0000 when the lamp hours are reset.
Note: This option has a five-second delay to avoid inadvertent changes. To
reset the lamp hours, you must press and hold the <Enter> button for
at least five seconds.