GigE Line Scan Camera·User Manual
42
No.
Name
Description
5
Frame Burst End Active
The camera outputs signals to external devices when frame burst stops.
6
Soft Trigger Active
The camera outputs signals to external devices when software trigger starts.
7
Hard Trigger Active
The camera outputs signals to external devices when hardware trigger starts.
8
Counter Active
The camera outputs signals to external devices when counter trigger starts.
9
Timer Active
The camera outputs signals to external devices when timer trigger starts.
Regarding Counter And Timer Control, you can refer the table below for details.
Table 8-2 Description of Counter And Timer Control
Parameter
Read/Write
Description
Counter Selector
Read and write
It selects counter source. Counter 0 is available
only at present.
Counter Event Source
Read and write
It selects the signal source of counter trigger. It is
disabled by default.
Counter Reset Source
Read and write
It selects the signal source of resetting counter.
Software is available only. It is disabled by default.
Counter Reset
Write is available
under certain
condition
It resets counter and it can be executed when
selecting Software as Counter Reset Source.
Counter Value
Read and write
It is the counter value with the range of 1 to 1023.
Counter Current
Value
Read only
It displays the number of executed external trigger.
When selecting Line Mode as Strobe Source Selector, you can also set duration, delay and pre
delay for outputted signal.
Set Strobe Line Duration
After enabling strobe signal, you can set its duration. Click Digital IO Control > Strobe Line
Duration, and enter Strobe Line Duration.