Figure 8-5 Set Strobe Line Duration
When the Strobe Line Duration value is 0, the strobe duration is equal to the exposure time. When
the Strobe Line Duration value is not 0, the strobe duration is equal to Strobe Line Duration value.
Set Strobe Line Delay
The camera supports setting strobe line delay to meet actual demands. When exposure starts, the
strobe output doesn’t take effect immediately. Instead, the strobe output will delay according to
the strobe line delay setting.
Click Digital IO Control > Strobe Line Delay, and enter Strobe Line Delay according to actual
demands.
Figure 8-6 Set Strobe Line Delay
The sequence diagram of strobe line delay is shown below.
Figure 8-7 Sequence Diagram of Strobe Line Delay