The door can open by inpung the duress code when there is duress. At the same me, the
client can report the duress event.
Super Password
The specic person can open the door by inpung the super password.
Note
The duress code and the super code should be dierent.
Elevator Control
Steps
1.
Click
Conguraon → Access Control → Elevator Control Parameters .
2.
Check Enable Elevator Control.
3.
Set the elevator parameters.
Elevator No.
Select an elevator No. for
conguraon from the drop-down list.
Elevator Controller Type
Select an elevator controller from the drop-down list.
Interface Type
Select a communicaon type from the drop-down list for elevator communicaon.
If you select RS-485, make sure you have connected the device to the elevator controller with
RS-485 wire.
If you select Network Interface, enter the elevator controller's IP address, port No., user
name, and password for
communicaon.
Negave Floor Capacity
Set the negave oor number.
Note
●
Up to 4 elevator controllers can be connected to 1 device.
●
Up to 10 negave oors can be added.
●
Make sure the interface types of elevator controllers, which are connected to the same
device, are consistent.
Set RS-485 Parameters
You can set the RS-485 parameters including the peripheral, address, baud rate, etc.
Click Conguraon → Access Control → RS-485 Sengs .
Check Enable RS-485, and set the parameters.
DS-K1T341C Series Face Recognion Terminal User Manual
116