EasyManua.ls Logo

HIKVISION DS-K1T341C Series

HIKVISION DS-K1T341C Series
218 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The door can open by inpung the duress code when there is duress. At the same me, the
client can report the duress event.
Super Password
The specic person can open the door by inpung the super password.
Note
The duress code and the super code should be dierent.
Elevator Control
Steps
1.
Click
Conguraon → Access Control → Elevator Control Parameters .
2.
Check Enable Elevator Control.
3.
Set the elevator parameters.
Elevator No.
Select an elevator No. for
conguraon from the drop-down list.
Elevator Controller Type
Select an elevator controller from the drop-down list.
Interface Type
Select a communicaon type from the drop-down list for elevator communicaon.
If you select RS-485, make sure you have connected the device to the elevator controller with
RS-485 wire.
If you select Network Interface, enter the elevator controller's IP address, port No., user
name, and password for
communicaon.
Negave Floor Capacity
Set the negave oor number.
Note
Up to 4 elevator controllers can be connected to 1 device.
Up to 10 negave oors can be added.
Make sure the interface types of elevator controllers, which are connected to the same
device, are consistent.
Set RS-485 Parameters
You can set the RS-485 parameters including the peripheral, address, baud rate, etc.
Click Conguraon → Access Control → RS-485 Sengs .
Check Enable RS-485, and set the parameters.
DS-K1T341C Series Face Recognion Terminal User Manual