Loading...
Set the door unlocking duraon. If the door is not opened for
the set me, the door will be locked.
Note
The open duraon ranges from 5 s to 60 s.
Exit Buon Type
You can set the exit
buon as Remain Open or Remain Closed
according to your actual needs. By default, it is Remain Open.
Door Remain Open
Duraon with First Person
Set the door open duraon when rst person is in. Aer the
rst person is authorized, it allows mulple persons access the
door or other authencaon acons.
Serial Port Sengs
Set serial port parameters.
Steps
1. Click
Conguraon → Access Control → Serial Port Sengs .
2. Set the No., Baud Rate, Data Bit, Stop Bit and Parity.
3. Set the Peripheral Type as Card Reader, Card Receiver, QR
Code Scanner, Fingerprint Module or Disable.
4. Set the Peripheral Posion as Entrance or Exit.
5. You can view the external device model and peripheral
soware version.
6. Click Save.
Set Wiegand Parameters
You can set the Wiegand transmission direcon.
Steps
Note
Some device models do not support this funcon. Refer to the
actual products when conguraon.
1. Click Conguraon → Access Control → Wiegand Sengs .
2. Select Entrance or Exit.
3. Enable Wiegand funcon.
4. The wiegand transmission direcon is set Input by default.
Note
Input: the device can connect a Wiegand card reader.
5. Select Wiegand Mode.
6. Click Save to save the sengs.
Note
If you change the peripheral, and aer you save the device
parameters, the device will reboot automacally.
Set Terminal Parameters
You can set terminal parameters for accessing.
Click Conguraon → Access Control → Terminal Parameters .
You can set Working Mode as Permission Free Mode or Access
Control Mode.