7.7.2 Congure Device Parameters
Aer adding the access control device, you can set its parameters
such as network parameters.
Set RS-485 Parameters
You can set the access control device's RS-485 parameters
including the baud rate, data bit, the stop bit, parity type, ow
control type, communicaon mode, work mode, and connecon
mode.
Before You Start
Add access control device to the client, and make sure the device
supports RS-485 interface.
Steps
1. Enter the Access Control module.
2. On the
navigaon bar on the le, enter Advanced Funcon
More Parameters .
3. Select an access control device in the device list and click
RS-485 to enter the RS-485
Sengs page.
4. Select the serial port number from the drop-down list to set
the RS-485 parameters.
5. Set the baud rate, data bit, the stop bit, parity type, and
connecon mode in the drop-down list.
6. Click Save.
The congured parameters will be applied to the device
automacally.
When you change the connecon mode, the device will
reboot automacally.
Enable M1 Card Encrypon
M1 card encrypon can improve the security level of
authencaon.
Steps
Note
The funcon should be supported by the access control device
and the card reader.
1. Enter the Access Control module.
2. On the navigaon bar on the le, enter Advanced Funcon
More Parameters .
3. Select an access control device in the device list and click M1
Card
Encrypon to enter the M1 Card Encrypon page.
4. Set the switch to on to enable the M1 card encrypon
funcon.
5. Set the sector ID.
The sector ID ranges from 1 to 100.
6. Click Save to save the sengs.
7.8 Door Control
In Monitoring module, you can view the real-me status of the
doors managed by the added access control device. You can also
control the doors such as open/close the door, or remain the
door open/closed via the client remotely. The
real-me access
52

Table of Contents