Network Video Recorder User Manual
105
Exceptions Setup Interface
Setting Alarm Response Actions
Purpose:
Alarm response actions will be activated when an alarm or exception occurs,
including Event Hint Display, Full Screen Monitoring, Audible Warning (buzzer), Notify
Surveillance Center, Upload Picture to FTP, Trigger Alarm Output and Send Email.
Event Hint Display
When an event or exception happens, a hint can be displayed on the lower-left
corner of live view image. And you can click the hint icon to check the details.
Besides, the event to be displayed is configurable.
Go to Menu > Configuration > Exceptions.
Check Enable Event Hint.
Event Hint Settings Interface
Click the to set the type of event to be displayed on the image.
Event Hint Settings Interface
Click the OK button to finish settings.
Full Screen Monitoring