Routing Commands 20
© 2001- 2006 Hirschmann Automation and Control GmbH. All Rights Reserved.
Age Time (seconds) Is the time it takes for an ARP entry to age out. This value was configured into
the unit. Age time is measured in seconds.
Response Time (seconds) Is the time it takes for an ARP request timeout. This value was config-
ured into the unit. Response time is measured in seconds.
Retries Is the maximum number of times an ARP request is retried. This value was config-
ured into the unit.
Cache Size Is the maximum number of entries in the ARP table. This value was configured into
the unit.
Dynamic Renew Mode Displays whether the ARP component automatically attempts to renew
dynamic ARP entries when they age out.
Total Entry Count Current / Peak Field listing the total entries in the ARP table and the peak
entry count in the ARP table.
Static Entry Count Current / Max Field listing the static entry count in the ARP table and maxi-
mum static entry count in the ARP table.
The following are displayed for each ARP entry.
IP Address
Is the IP address of a device on a subnet attached to an existing routing interface.
MAC Address Is the hardware MAC address of that device.
Interface Is the routing slot/port associated with the device ARP entry.
Type Is the type that was configured into the unit. The possible values are Local, Gateway,
Dynamic and Static.
Age This field displays the current age of the ARP entry since last refresh (in hh:mm:ss
format
4.1.11 show arp brief
This command displays the brief Address Resolution Protocol (ARP) table information.
Format show arp brief
Mode Privileged EXEC
Age Time (seconds) Is the time it takes for an ARP entry to age out. This value was configured into
the unit. Age time is measured in seconds.
Response Time (seconds) Is the time it takes for an ARP request timeout. This value was config-
ured into the unit. Response time is measured in seconds.
Retries Is the maximum number of times an ARP request is retried. This value was config-
ured into the unit.
Cache Size Is the maximum number of entries in the ARP table. This value was configured into
the unit.
Dynamic Renew Mode Displays whether the ARP component automatically attempts to renew
dynamic ARP entries when they age out.
Total Entry Count Current / Peak Field listing the total entries in the ARP table and the peak
entry count in the ARP table.
Static Entry Count Current / Max Field listing the static entry count in the ARP table and
maximum static entry count in the ARP table.