Command Structure 6
© 2001- 2006 Hirschmann Automation and Control GmbH. All Rights Reserved.
1.1.4 Conventions
Network addresses are used to define a link to a remote host, workstation or network.
Network addresses are shown using the following syntax:
Double quotation marks such as "System Name with Spaces" set off user defined
strings. If the operator wishes to use spaces as part of a name parameter then it must be
enclosed in double quotation marks.
Empty strings (““) are not valid user defined strings.
Command completion finishes spelling the command when enough letters of a com-
mand are typed to uniquely identify the command word. The command may be exe-
cuted by typing <enter> (command abbreviation) or the command word may be
completed by typing the <tab> or <space bar> (command completion).
The value 'Err' designates that the requested value was not internally accessible. This
should never happen and indicates that there is a case in the software that is not han-
dled correctly.
The value of '-----' designates that the value is unknown.
1.1.5 Annotations
The CLI allows the user to type single-line annotations at the command prompt for use when
writing test or configuration scripts and for better readability. The exclamation point (‘!’)
character flags the beginning of a comment. The comment flag character can begin a word
anywhere on the command line and all input following this character is ignored. Any
command line that begins with the character ‘!’ is recognized as a comment line and ignored
by the parser.
Some examples are provided below:
! Script file for setting the CLI prompt
set prompt example-switch
! End of the script file
1.1.6 Special Characters
Certain special key combinations speed up use of the CLI. They are listed in this section. Also,
help is available for the CLI by typing HELP:
BS delete previous character
Ctrl-A go to beginning of line
Table 1. Network Address Syntax
Address Type Format Range
ipaddr
192.165.11.110 0.0.0.0 to 255.255.255.255
(decimal)
macaddr
A7:C9:89:DD:A9:B3 hexidecimal digit pairs

Other manuals for Hirschmann PowerMICE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann PowerMICE and is the answer not in the manual?

Hirschmann PowerMICE Specifications

General IconGeneral
BrandHirschmann
ModelPowerMICE
CategoryNetwork Router
LanguageEnglish

Related product manuals