4.6 Operating the device
Perform the following steps to start up the device:
Installing terminal blocks, switching on the supply voltage
Connecting data cables
4.6.1 Installing terminal blocks, switching on the supply
voltage
By connecting the supply voltage via the terminal block, you start the
operation of the device.
4.6.2 Connecting data cables
Note the following general recommendations for data cable connections in
environments with high electrical interference levels:
Keep the length of the data cables as short as possible.
Use optical data cables for the data transmission between the buildings.
When using copper cables, provide a sufficient separation between the
power supply cables and the data cables. Ideally, install the cables in
separate cable channels.
Verify that power supply cables and data cables do not run parallel over
longer distances. If reducing the inductive coupling is necessary, verify
that the power supply cables and data cables cross at a 90° angle.
Use SF/UTP cables as per ISO/IEC 11801:2002.
Connect the data cables according to your requirements.