50
Installation SPIDER PL
Release
08
09/2018
9.4 Electromagnetic compatibility (EMC)
EMC interference emission Standard
applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Merchant Navy
b
b. Merchant Navy – applies to devices with the approval codes WU, U9, UY, UX, UT, VU
Railway
applications
(trackside)
c
c. EN 50121-4 – applies to devices with the approval codes UT, T9, TY, VT, R9, RT, RY
Sub-station
applications
d
d. EN 61850-3, IEEE 1613 – applies to devices with the approval codes V9, VY, VU, VT, R9
Radiated emission
EN 55032 Class A Class A Class A Class A
DNV GL Guidelines — EMC 1 — —
FCC 47 CFR Part 15 Class A Class A Class A Class A
EN 61000-6-4 Fulfilled Fulfilled Fulfilled Fulfilled
Conducted emission
EN 55032 Supply connection Class A Class A Class A Class A
DNV GL Guidelines Supply connection — EMC 1 — —
FCC 47 CFR Part 15 Supply connection Class A Class A Class A Class A
EN 61000-6-4 Supply connection Fulfilled Fulfilled Fulfilled Fulfilled
EN 55032 Telecommunication
connections
Class A Class A Class A Class A
EN 61000-6-4 Telecommunication
connections
Fulfilled Fulfilled Fulfilled Fulfilled
EMC interference immunity Standard
applications
a
Marine
applications
b
Railway
applications
(trackside)
c
Sub-station
applications
d
Electrostatic discharge
EN 61000-4-2
IEEE C37.90.3
Contact discharge ±4 kV ±6 kV ±6 kV ±8 kV
EN 61000-4-2
IEEE C37.90.3
Air discharge ±8 kV ±8 kV ±8 kV ±15 kV