Forced set/reset with I/O number designation
(Random N points)
Designates N points (words) of I/O numbers randomly, and forcibly sets the designated data or resets the
data area.
READ occupation
WRITE occupation
Not occupied
- - - -
(a) Number of bits / Number of words H01 to H28 (1 to 40)
(b) I/O code (refer to the I/O code table)
(c) I/O number (refer to I/O number decimal/hexadecimal conversion chart)
(d) Set / reset data
(Bit data)
(a) Response task code
For task codes other than the normal task codes, refer to the “response list by
task code” at the end of this chapter.
* The EH-150 returns “H00” (normal execution) even for I/Os that are out of
range.
Write 2 words to WR100 and WR10A. (WR100=HABCD, WR10A=HDCBA)
Request : STX 2 FFFF0000 45 02 0A 000100 ABCD 0A 00010A DCBA 1E CR
Request (ASCII) : 02 32 4646464630303030 3435 3032 3041 303030313030 41424344
3041 303030313041 44434241 3145 0D
Response : STX FFFF0000 00 45 SUM CR