Error code
(SSB2)
Description
B994 The Swap Resync operation cannot be performed because the S-VOL is not in PSUS or
SSWS status. (Swap Resync resynchronizes differential data when the S-VOL is
swapped for the P-VOL.)
B998 The pair cannot be created because the secondary system path setting is invalid.
B99B The pair cannot be created because TC Asynchronous is not supported.
B9BD The DKC LDEV configuration might have been changed while starting CCI. Restart CCI.
B9C0 The source of the command device has run out. In LUN Manager, set the command
device to OFF, then to ON.
C162 The pair cannot be resynchronized because the pair was not in the Suspend status.
C16B The pair cannot be created because the S-VOL is not available.
C184 A request for a Pairsplit-S operation was rejected because the status change of the S-
VOL failed.
C189 A request for a Pairsplit-S operation was rejected because the pair status was invalid.
C18A A request for a Pairsplit-S operation was rejected because the corresponding volume or
group was changing status.
C194 The pair cannot be split because the S-VOL pair status was in transition.
C195 A request for a Pairsplit-r operation was rejected because the pair status was already
PSUS (by user) PSUS (because of failure).
C198 Pair split cannot run because the group includes no pair that can be split.
C199 A request for a Pairsplit-r operation was rejected because the corresponding volume or
group was changing status.
C1BE The pair's status cannot be changed during the power-on processing of the DKC.
C1D6 The command was rejected because it was issued to a non-TC volume.
C211 The command was rejected because the specified volume is a P-VOL. If the error occurs
when the volume is unpaired, select the volume in Device Manager - Storage Navigator,
release the pair using the Force Delete Pairs (TC Pairs) window, and then run the
command again.
C212 The command was rejected because the specified volume is an S-VOL. If the error
occurs when the volume is unpaired, select the volume in Device Manager - Storage
Navigator, release the pair using the Force Delete Pairs (TC Pairs) window, and then
run the command again.
C214 The command was rejected because the secondary system is not registered, or the
registered information is invalid.
C215 The command was rejected because an internal logical error has occurred.
C218 The command was rejected because the pair status is invalid.
C21A The command was rejected because the P-VOL status is other than PSUS (by user)
PSUS (because of failure).
C21C The command was rejected because the secondary system is not registered, or the
registered information is invalid.