6. RAS FEATURES IN HF-W100E/IoT
6-4
<Explanation>
The GendoControlN function sets the output state of the general purpose output with
usiOuput and specifies a control target with usiMask. Figure 6-1 shows an operation
example to illustrate the relationship between usiOutput and usiMask.
Figure 6-1 Operation Example of the GendoControlN Function
<Supplementary information>
Figure 6-2 shows the operation of the general purpose output1 when the
GendoControlN function is used. The dashed lines show the general purpose output
level, and the bold line show the transition of the general purpose output1.
Figure 6-2 Operation Example of the External General Purpose Output1
<Program example>
For an example of a program using this function, see “6.2.3 Examples of using the
RAS library”.
features to control the external general purpose I/O. In the presence of
contention caused by simultaneous access, the output cannot be controlled