2. SETUP
2-4
2.2.3 License activation procedure
(1) Online activation
(a) Using the CODESYS development environment
1. Start the CODESYS development environment in the following steps. Wait until
the startup process is complete. Be aware that it may take dozens of seconds.
If the OS is Windows® Embedded Standard 7, click Start, and click All
Programs > 3S CODESYS > CODESYS > CODESYS V3.5 SP10 Patch1.
If the OS is Windows® 10, click Start, and click 3S CODESYS > CODESYS >
CODESYS V3.5 SP10 Patch1 from the list of applications.
(Alternatively, double-click the CODESYS V3.5 SP10 Patch1 icon on the
desktop.)
2. The CODESYS development environment starts. Click New Project. Create a new
project as follows.
• Categories: Projects
• Templates: Standard project
• Name: Any
• Location: Any
• Device: Different depending on the model you purchased. Select as follows.
Model name
Device name
Motion model
HJ-100E RTE SoftMotion 64bit (Hitachi Industry & Control Solutions, Ltd.)
CNC model
HJ-100E RTE CNC 64bit (Hitachi Industry & Control Solutions, Ltd.)
PLC_PRG in: Any