Caution Description
If you set Server Priority Manager using Storage Navigator, you
cannot set Server Priority Manager using CCI. You need to delete
all Server Priority Manager settings made using Storage Navigator
(for instructions see the Performance Guide), and then use Server
Priority Manager from CCI to make the Server Priority Manager
settings.
Performance
Monitor of
Device Manager
- Storage
Navigator
If you set Server Priority Manager using CCI, you cannot use a part of
Performance Monitor of Device Manager - Storage Navigator. For
details, see the Performance Guide.
Maintenance When you perform the following operations, the upper limit value
control might be disabled for about two minutes:
Adding, replacing, or removing cache memory
Changing the system configuration
Updating the firmware
VSP Gx00 models and VSP Fx00 models: Replacing the controller
(CTL)
VSP Gx00 models and VSP Fx00 models: Adding, replacing, or
removing front-end module (CHB)
VSP G1000, VSP G1500, VSP F1500: Replacing MP blades
VSP G1000, VSP G1500, VSP F1500: Adding, replacing, or
removing front-end directors (CHAs)
Powering on and off the storage system
Note: The upper limit value control might be disabled when an
abnormal condition that causes the login or logout of the host occurs,
such as a network failure or damage on the HBA or Fibre cable.
Resolve the cause of the unexpected login/logout behavior, and then
enable the upper limit value control.
When specifying
ports and WWNs
of HBAs:
Deleting SPM
names or SPM
group names
If you delete a combination of the specified port and the WWN of the
HBA from the SPM targets by using the SPM name, the SPM setting
and SPM name under the specified port are deleted. If the same SPM
name is set to another port, only the SPM setting of the specified port
is deleted.
If you delete a combination of the specified port and the WWN of the
HBA from the SPM targets by using the SPM group name, the SPM
setting and the group under the specified port are deleted. If the same
SPM group name is set to another port, only the SPM setting of the
specified port is deleted.
When specifying
ports and WWNs
of HBAs:
Resource group
function and
restrictions for
Server Priority
Manager
When you use the resource group function, the range of operation is
limited per port of resource group by Server Priority Manager. The
threshold value, the SPM name, and the SPM group name, which are
managed in the entire system, are common among the resource
groups.
When you perform Server Priority Manager operations using the
resource group function, share the threshold value that the storage
administrator determines among users of resource groups. Determine
rules for SPM names and SPM group names including port names to
avoid redundant names between ports.