Loading...
CL1-A
CL1-An where n: unit ID for multiple RAID
Specifying the port name with a host group
CL1-A-g where g: host group
CL1-An-g where n-g: host group=g on CL1-A in unit ID=n
Commands and options including a host group
(1) Specifiable command for host group
The following commands can specify a host group with the port strings:
raidscan -p <port#>, raidar -p <port#>, raidvchkscan -p <port#>
# raidscan -p CL2-D-1
PORT# /ALPA/C,TID#,LU#.Num(LDEV#....)...P/S,
Status,Fence,LDEV#,P-Seq#,P-LDEV#
CL2-D-1 /da/ 0, 4, 0.1(256)...........SMPL ---- ------ ----,
----- ----
CL2-D-1 /da/ 0, 4, 1.1(257)...........SMPL ---- ------ ----,
----- ----
CL2-D-1 /da/ 0, 4, 2.1(258)...........SMPL ---- ------ ----,
----- ----
(2) Command option including a host group
CCI supports new option for the following commands in order to show a LUN
on the host view by finding a host group via the specified device.
raidscan -pdg <device>, raidar -pdg <device>, raidvchkscan -pdg
<device>
# raidscan -pdg /dev/rdsk/c57t4d1
PORT# /ALPA/C,TID#,LU#.Num(LDEV#....)...P/S,
Status,Fence,LDEV#,P-Seq#,P-LDEV#
CL2-D-1 /da/ 0, 4, 0.1(256)...........SMPL ---- ------ ----,
----- ----
CL2-D-1 /da/ 0, 4, 1.1(257)...........SMPL ---- ------ ----,
----- ----
CL2-D-1 /da/ 0, 4, 2.1(258)...........SMPL ---- ------ ----,
----- ----
Specified device(hgrp=1) is LDEV# 0257
raidscan -findg
# ls /dev/rdsk/c57* | raidscan -findg
DEVICE_FILE UID S/F PORT TARG LUN SERIAL LDEV
PRODUCT_ID
/dev/rdsk/c57t4d0 0 F CL2-D-1 4 0 62500 256
OPEN3-CVS-CM
/dev/rdsk/c57t4d1 0 F CL2-D-1 4 1 62500 257
OPEN3-CVS
/dev/rdsk/c57t4d2 0 F CL2-D-1 4 2 62500 258
OPEN3-CVS
raidscan -findg conf, mkconf -gg
# ls /dev/rdsk/c57* | raidscan -findg conf 0 -g ORA
HORCM_DEV
Examples of using CCI commands
8-15