CL1-A-0 ef 0 0 9 62496 1 21 SMPL - -
30053 32
CL1-A-0 ef 0 0 10 62496 1 22 SMPL - -
30053 33
E-Seq#: Displays the production (serial) number of the external LUN. E-
LDEV#: Displays the LDEV# of the external LUN.
(3) Command for confirming the status
It is possible to confirm the status for Volume Migration by using "-fe" option
of the pairdisplay command.
pairdisplay -g <group> -fe
-fe
This option is used to display the serial# and LDEV# of the external LUNs
mapped to the LDEV and additional information for the pair volume.
This option displays the information above by adding to last column, and then
ignores the format of 80 column.
This option is invalid if the cascade options (-m all,-m cas) are specified.
Display example:
Before execution of Volume Migration command:
# pairdisplay -g horc0 -fe
Group ... Seq#,LDEV#.P/S,Status, Seq#,P-LDEV# M CTG CM EM E-Seq# E-
LDEV#
horc0 ... 62496 18.SMPL ---,----- --- - - - - -
-
horc0 ... 62496 19.SMPL ---,----- --- - - - H 30053
30
# paircreate -g horc0 -vl -m cc
During execution of Volume Migration command, the progress is displayed in
the copy %:
# pairdisplay -g horc0 -fe
Group ... Seq#,LDEV#.P/S,Status, Seq#,P-LDEV# M CTG CM EM E-Seq# E-
LDEV#
horc0 ... 62496 18.P VOL COPY,62496 19 - - C - -
-
horc0 ... 62496 19.S VOL COPY,----- 18 - - C H 30053
30
After completion of Volume Migration command:
Group ... Seq#,LDEV#.P/S,Status, Seq#,P-LDEV# M CTG CM EM E-Seq# E-
LDEV#
horc0 ... 62496 18.P VOL PSUS,62496 19 - - C V 30053
30
horc0 ... 62496 19.S VOL SSUS,----- 18 - - C - -
-
6-40
Data replication operations with CCI
Command Control Interface User and Reference Guide