41 33-00462—05
9190
Dehumidification
Dehumidification Away
mode Fan Control
On, automatic, circulate 9180 = allowed No T10+
9200
Dehumidification
Dehumidification Away
mode low limit
temperature setting
70-80F (21.0C-26.5C) 9180 = allowed No T10+ The
dehumidification
Away mode setting
can restrict this
Dehumidification Away
Mode Temperature
Setting
70F to 99F (21.0C to 37.0C) 9180 = allowed No T10+ The
dehumidification
Away mode Low
Limit setting can
restrict this
Dehumidification Away
Mode Dehumidification
Setting
40% - 70% 9180 = allowed No T10+
9210
Dehumidification
Dehumidifier Filter
replacement reminder
Off, 30, 60, calendar days;
3, 4, 5, 6, 7, 8, 9, 10, 11, 12,
calendar months.
No Both
10000 Ventilation Ventilation Type None, ERV/HRV, Passive
(Fan Only), Fresh Air
Damper,
ERV/HRV or
damper needs
Available U
contacts.
"Passive Fan"
not an option
for Radiant
heat only.
No Both
10005 Ventilation Ventilator Model number Other model
VNT5070E1000
VNT5200E1000
ISU 10000 set
to ERV/ HRV
No T10+ Information in
Ventilation section
10020 Ventilation What terminals are wired
to the ventilation
equipment?
None, EIM U1, EIM U2, EIM
U3
10000 =
ERV/HRV or
Fesh air
damper
Yes T10+ If an EIM is not
used this ISU isn't
shown and
ventilator wires to U
contacts at UWP
10050 Ventilation Ventilation control
method
ASHRAE or Percent on
Time
10000 =
ERV/HRV or
Fesh air
damper
No Both
10060 Ventilation Ventilation Fan control Thermostat controls fan or
Equipment controls fan
10000 =
ERV/HRV or
Fresh air damper
And 8000 set for
humidifier
No Both
10065 Ventilation Turn on ventilation dry
contacts
Custom Alert 1 - Custom
Alert 4 (options depend on
6005 settings)
ISU 6005 is set
for a custom
dry contact
alert & ISU
10140 isn’t
selected for the
same custom
alert.
Yes T10+ If enabled, the
ventilator will come
on whenever
the selected Dry
Contact Alert is
active
10090 Ventilation Ventilation House Size
Number of Bedrooms 1-6
10050 =
Ashrae
No Both
Size of house 1000 -5000
sq. ft. if display set to
Fahrenheit; 90-460 sq. M. if
set to Celsius
10050 =
Ashrae
No Both
Table 9. Installer Setup (ISU). (Continued)
Firmware is occasionally updated at the factory or over the air. Some ISU settings may not be shown on models that lack the latest firmware.
ISU # Heading Question Options
Contingent
previous
setting?
EIM
needed?
T10, T10+
or both Notes

Table of Contents

Other manuals for Honeywell Home T10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Home T10 and is the answer not in the manual?

Honeywell Home T10 Specifications

General IconGeneral
ConnectivityWi-Fi
GeofencingYes
DisplayTouchscreen
SensorsTemperature, Humidity
Power SourceC-Wire (Required)
Energy SavingYes, with scheduling and geofencing
Voice ControlAmazon Alexa, Google Assistant
Smart Home PlatformHoneywell Home App
Compatibility with SystemsWorks with most HVAC systems
Warranty5-year limited warranty

Related product manuals