Mounting and Wiring the Control
3-5
Zone Type Description
Type 01
Entry/Exit Burglary #1
Assign to zones that are used for primary entry and exit.
Provides entry delay when zone type is faulted if control is armed in the
Away, Stay, or Night-Stay modes.
No entry delay provided when the panel is armed in the
Instant/Maximum mode.
Entry delay #1 is programmable for each partition.
Exit delay begins whenever the control is armed, regardless of the
arming mode selected, and is programmable for each partition. (If Final
Contact Set exit option is selected in field *88, exit delay remains on
indefinitely until the last zone in zone list 8 is restored; once the last
zone is restored, exit delay is then 5 seconds.)
Type 02
Entry/Exit Burglary #2
Assign to zones that are used for entry and exit and require more time
than the primary entry/exit point.
Provides a secondary entry delay, in same manner as entry delay #1.
Entry delay #2 is programmable for each partition.
Exit delay is the same as described for Type 01.
Type 03
Perimeter Burglary
Assign to all sensors or contacts on windows and infrequently used
exterior doors.
Provides an instant alarm if the zone is faulted when the panel is armed
in the Away, Stay, Night-Stay, Instant or Maximum modes.
Type 04
Interior Follower
Assign to a zone covering an area such as a foyer, lobby, or hallway
through which one must pass upon entry (to and from the keypad).
Provides a delayed alarm (using the programmed entry 1 time) if the
entry/exit zone is faulted first. Otherwise this zone type gives an instant
alarm.
Active when the panel is armed in the Away mode.
Bypassed automatically when the panel is armed in the Stay or Instant
modes;
if armed in Night-Stay mode, zones assigned to zone list 05 (night-stay
zone list) are not bypassed when system armed in Night-Stay mode.
Type 05
Trouble when
Disarmed/
Alarm when Armed
Assign to a zone covering a sensitive area such as a stock room, drug
supply room, emergency exit door, etc.
Can also be used with a sensor or contact for an area where immediate
notification of an entry is desired.
Assign for use with sensor, device, or sounder tamper protection.
Provides an instant alarm if faulted when armed in the Away, Stay,
Night-Stay, Instant or Maximum modes.
During the disarmed state, the system will provide a latched trouble
sounding from the keypad (and a central station report, if desired).
Type 06
24-hour Silent Alarm
Usually assigned to a zone containing an emergency button.
Sends a report to the central station but provides no keypad display or
sounding.
Type 07
24-hour Audible Alarm
Assign to a zone that has an emergency button.
Sends a report to the central station, and provides an alarm sound at the
keypad, and an audible external alarm.