Data Field Programming
4-9
Miscellaneous System Fields
FIELD
TITLE and DATA ENTRIES EXPLANATION
*77
Summer Time
Start/End Month
0 = Disabled 4 = April
1 = Jan # + 10 = Oct
2 = Feb # + 11 = Nov
3 = Mar # + 12 = Dec
Enter the start and end month for summer time, if
applicable to the region.
*78
Summer Time
Start/End Weekend
0 = disabled 4 = fourth
1 = first 5 = last
2 = second 6 = next to last
3 = third 7 = third to last
Enter the start and end weekend for summer time, if
applicable to the region.
*84
Auto-Stay Arm
0 = no
1 = partition 1 only
2 = partition 2 only
4 = partition 3 only
Add values for multiple partitions (e.g. for
partitions 1 and 2, enter 3).
If enabled, the system will automatically change
AWAY or MAXIMUM modes to STAY and INSTANT
modes respectively if the entry/exit door is not opened
and closed within the exit delay time after a user arms
in AWAY mode from a wired keypad (non-RF device).
An Opening report followed by an Armed Stay report is
sent to the Central Station.
If the door is opened and closed within the exit delay
period, the system remains in AWAY or MAXIMUM
mode.
Any RF device that arms the system AWAY overrides
this feature and the system remains armed in the
AWAY mode.
NOTE: Must not be used if TeleCommand is used.
Does not apply if:
Final Contact Set exit option (field *88, option
3) is enabled.
Blockschloss is being used.