EasyManua.ls Logo

Honeywell Ademco Vista-12D - Siren Options

Honeywell Ademco Vista-12D
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation and Setup Guide
4-16
FIELD
TITLE and DATA ENTRIES EXPLANATION
*176
Siren Options
Entry 1: 0 = external siren
1 = self-activated external siren
Entry 2: 0 = disable delay
1 = enable 30 second siren delay
and dialer delay during entry
delay period
2 = enable stay siren delay
Select desired options.
Entry 2, if 1: When entry delay is active and an instant
zone is faulted, the siren is delayed 30 seconds and the
report is delayed 30 seconds, unless field *50 is set for a
greater delay (the 30-second dialer delay supersedes
values less than 30 seconds set in field *50).
Entry 2, if 2: When armed in the Stay mode and an
alarm event occurs, the siren output will be delayed by
the amount of time that the entry delay 1 is set for.
*177
Device Duration 1, 2
Duration 1:
0 = 15 secs 6 = 2-1/2 min #+12 = 8 min
1 = 30 secs 7 = 3 min #+13 = 10 min
2 = 45 secs 8 = 4 min #+14 = 12 min
3 = 60 secs 9 = 5 min #+15 = 15 min
4 = 90 secs #+10 = 6 min
5 = 2 min #+11 = 7 min
Duration 2: 1 through 7 for number of days
These entries set the duration for output action options
5 (duration 1) and 6 (duration 2) programmed in 80
Output Function Programming.
Duration 2 can be used as a strobe timer.
*178
RF Supervision / RF Jam Option
0 = RF supervision and RF jam detection
reporting
1 = Report RF supervision failure as tamper
alarm when armed
2 = Report RF Jam as tamper alarm when
armed
3 = Report RF Jam and RF supervision
failure as tamper alarm when armed**
Select desired option. See field *22 for related options.
Entry 0: RF jam conditions report as Trouble zone 90
(Contact ID code 344, RF Rcvr Jam Detect)
plus a zone trouble report for each RF zone in
the system (CID code 383, Trouble Sensor
Tamper) when the system is armed or
disarmed. Keypads display Tamper zz (zz =
zones) and Tamper 90 (fixed-word) or
RECEIVER JAM (alpha).
RF supervision failures report as zone troubles
(CID code 381, RF Sensor Super.) when the
system is armed or disarmed. Keypads display
CHECK zz (zz = zone).
Entry 1: Same as entry 0 except RF supervision failures
report as zone alarms (CID code 144, Alarm
Sensor Tamper) when the system is armed;
keypads display ALARM zz.
Entry 2: Same as entry 0 except RF jam conditions
report as zone alarms (Contact ID code 144,
Alarm Sensor Tamper) when the system is
armed; keypads display ALARM zz.
Entry 3: Same as entry 0 when disarmed, but when the
system is armed, both RF jam conditions and
RF supervision failures report as zones alarms
(Contact ID code 144, Alarm Sensor Tamper)
NOTES: RF Jam must be enabled in field *22 in order
for any RF reporting to be enabled in this field.
Alarm restore reports must be enabled (field *70) in
order for RF Supervision/RF Jam alarm restores to be
reported.
Trouble reports and trouble restore reports must be
enabled (fields *60, *71) in order for RF supervision/RF
jam trouble conditions and restores to be reported.
** Must be “3” for prEN50131-5-3 Class 2 compliance

Table of Contents