Data Field Programming
4-19
Keypad Programming Fields
NOTE: Each keypad must be assigned a unique address. Keypads programmed with the same address will
give unpredictable results.
FIELD
TITLE and DATA ENTRIES EXPLANATION
*190
Keypad 2 Device Address 17
Entry 1 – Partition Assignment:
0 = keypad disabled 2 = partition 2
1 = partition 1 3 = common
Entry 2 – Sound Option:
0 = no suppression
1 = suppress arm/disarm and E/E beeps
2 = suppress chime beeps only
3 = suppress arm/disarm, E/E beeps and
chime beeps
Keypad 2
Entry 1: enter the partition in which the keypad is
located
Entry 2: Enter the desired sound option for this
keypad.
NOTE: Address 16 is reserved for keypad 1, which is
factory set to partition 1 with all sounds enabled.
*191
Keypad 3 Device Address 18
See field *190 for entries.
Keypad 3
See field *190 for explanation.
*192
Keypad 4 Device Address 19
See field *190 for entries.
Keypad 4
See field *190 for explanation.
*193
Keypad 5 Device Address 20
See field *190 for entries.
Keypad 5
See field *190 for explanation.
*194
Keypad 6 Device Address 21
See field *190 for entries.
Keypad 6
See field *190 for explanation.
*195
Keypad 7 Device Address 22
See field *190 for entries.
Keypad 7
See field *190 for explanation.
*196
Keypad 8 Device Address 23
See field *190 for entries.
Keypad 8
See field *190 for explanation.