Installation and Setup Guide
4-8
FIELD
TITLE and DATA ENTRIES EXPLANATION
*63
Low Battery Report Code
0 = disable; 1-F = see description above 59
Sent when a low-battery condition exists in the
system’s battery.
*64
Test Report Code
0 = disable; 1-F = see description above 59
Sent periodically to test that the communicator and
phone lines are operational. Frequency of report is set in
Scheduling mode (event 11).
*65
Open Report Code
0 = disable; 1-F = see description above 59
Sent upon disarming of the system in the selected
partitions.
*66
Arm Away/Stay Report Code
0 = disable; 1-F = see description above 59
This option allows for independent programming of
Away and Stay reports for each partition.
NOTE: “OPEN” reports are not sent if the associated
closing report is not enabled.
*67
RF Low Battery Report Code
0 = disable; 1-F = see description above 59
Sent when a wireless transmitter low-battery condition
exists.
*68
Cancel Report Code
0 = disable; 1-F = see description above 59
Sent upon disarming of the system after an alarm
condition was reported.
*69
Alarm Restores
Send restore code (if fault cleared):
0 = at siren timeout (if restored) or at disarm
(whether restored or not)
1 = dynamically as the fault clears
2 = only after a disarm
Alarm restore message will be sent upon condition
selected.
*70
Alarm Restore Report Code
0 = disable; 1-F = see description above 59
Sent when an alarm zone is restored to its non-faulted
condition or at the times selected in field *69.
*71
Trouble Restore Report Code
0 = disable; 1-F = see description above 59
Sent when a trouble in a zone is restored
*72
Bypass Restore Report Code
0 = disable; 1-F = see description above 59
Sent when a zone that has been bypassed is
unbypassed, either manually or when the
partition/system is disarmed.
*73
AC Mains Restore Report Code
0 = disable; 1-F = see description above 59
Sent when AC mains has been restored after an AC
mains outage.
*74
Low Battery Restore Report Code
0 = disable; 1-F = see description above 59
Sent when a system low-battery condition is restored
to normal.
*75
RF Low Battery Restore Code
0 = disable; 1-F = see description above 59
Sent when a transmitter’s low battery condition is
restored (i.e., new battery installed).
*76
Test Restore Report Code
0 = disable; 1-F = see description above 59
Sent when the Test mode is exited.

Table of Contents