Mounting and Wiring the Control
3-9
Loading Factory Defaults/Initializing for Download
To Load Default Entries
Press 97 while in Program Mode. This resets all data fields to
the default values shown on the Program Form. Use
97 only if
you wish to return to the original factory-programmed defaults.
To Initialize Download ID
Press 96 while in Program Mode. This initializes the system for
downloading and resets all the subscriber account numbers and
CSID.
Do not press
97 to load defaults if any programming has been done
previously—data already programmed into the system will be changed!
4
Exiting the Programming Mode
Prevent installer code reentry
Press 98. Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming mode if
98 was used to exit, you must first power the system down.
Then power up again, and press [] and [#] at the same time,
within 50 seconds of powering up.
Allow installer code reentry
Press 99. Exits Programming Mode and allows re-entry by:
Installer Code + [ 8] + [0] + [0] or by: Pressing [] and [#] at the
same time, within 50 seconds of power-up.
Table of Device Addresses
This Device Uses Address
Reports as
††
Enabled By
RF Receiver 00 100 *56 zone programming: input device type entry
Alternative Communication
Media (ACM)
03 103 automatic if output to ACM field *29 enabled
Telecommand Voice Module 17-23 117-123 same as keypad enables; see below
Zone Expanders** (4219/4229):
zones 17 - 24
08
108
*56 zone programming: input device type entry, then:
automatic if zone no. 17-24 entered as AW type or
relay assigned
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
16
17
18
19
20
21
22
23
116
117
118
119
120
121
122
123
data field programming as listed below:
always enabled for partition 1, all sounds enabled.
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
5800TM Module 28 n/a automatic
† ACM devices include: 7845i Ethernet Interface Internet/Intranet, AI4164RS/AI4164ETH RS485/Ethernet
Eureka Network Interface
†† Addressable devices are identified by “1” plus the device address when reporting. Enter a report code for
zone 91 to enable addressable device reporting (default = reports enabled). See field *199 for addressable
device (ECP) 3-digit/2-digit identification keypad display options
.
** or 6164 Keypad using zones; 08 = zones 17-20

Table of Contents

Related product manuals