Installation and Setup Guide
5-6
PROMPT
VALID ENTRIES EXPLANATION
XMIT TO CONFIRM
PRESS TO SKIP
Confirmation Option
Activate the loop input or button
[] to continue
This prompt will only appear if you answered
“Yes” at the first prompt in this section.
The system will enter a confirmation mode so that
the operation of the actual programmed input can
be confirmed.
Activate the loop input or button that corresponds
to this zone.
If the serial number and/or loop number
transmitted does not match the serial number
entered, a display similar to the one below appears.
Entd A022-4063 1
Rcvd A022-4064 1
If so, activate the loop input or button on the
transmitter once again. If a match is not obtained
(i.e., summary display does not appear), press the
[#] key twice and then enter (or transmit) the
correct serial number.
Press [] to continue.
Zn ZT RC In: L
17 03 10 RF: 1s
Summary Screen
[] to continue
If the serial number transmitted matches
the serial number entered, the keypad will
beep 3 times and a summary display will
appear, showing that zone's programming.
Note that an “s” indicates that a
transmitter’s serial number has been
enrolled.
Press [] to accept the zone information and
continue.
PROGRAM ALPHA?
0 = NO 1 = YES 0
Alpha Descriptors
0 = no
1 = yes
[] to continue
If you want to program descriptors for zones now,
enter 1 (Yes) and refer to the Alpha Descriptor
Programming section for the procedure to use.
ENTER ZN NUM.
(00 = QUIT) 11
Next Zone Number
00 = quit
[] to continue
If 0 (No) was entered above, the system will return
you to the ENTER ZN NUM. prompt for the next
zone.
When all zones have been programmed, enter 00
to quit.